The assembly, replacement, and adjustment of a circular knitting machine are essentially an error-control chain: establish the datum during assembly, restore the datum during replacement, verify the datum during adjustment, and finally use fabric quality for the final inspection. Any deviation in any link will be amplified and revealed on the fabric. The following content is compiled from professional maintenance references. For specific operations, always follow the machine manufacturer’s manual; electrical work must be performed by certified personnel.
---
I. Assembly: Establish the Datum
The essence of machine assembly is to control the manufacturing errors of each part within an acceptable range. The core sequence is: level the main table → cylinder/dial datum → cams and yarn feeding system → electrical and safety devices.
The first step is always leveling the main table. Place the main machine on a concrete floor thicker than 150 mm. Place a spirit level on the main table surface near the three machine feet, adjust the main and auxiliary foot screws and insert steel shims, level the main table surface, and then lock it. If the main table is not level, the cylinder will wobble when rotating, and all subsequent cam clearances and tensions will drift accordingly.
After the main table is fixed, install the yarn feeding system, feed belt, creel, and lint removal device in sequence. Adjust the feed belt tension so that the yarn storage feeders do not slip; adjust the center of gravity of the lint fan so that it can stop at any position when the machine stops. The fan blade fixing screws must be tightened and included in weekly inspection. The needle detector and electrical wiring must be completed by certified personnel.
There is another detail at the assembly stage: try not to add shims at the connection between the cylinder and the large gear. Roundness should be adjusted by eccentric positioning wheels or set screws, not “found” back with shims. Shims introduced at the assembly stage will become hidden risks for future precision drift.
---
II. Replacement: Restore the Datum
When replacing parts, what really needs to be done is to return the machine to the datum state it had before replacement. The general principle is: mark before removal, install in the correct position, and recheck clearance and runout.
The cylinder is the precision origin. After replacement, its center alignment with the sinker ring must be recalibrated. Radial runout is achieved by centering the locating shoulder of the cam box base ring; the standard is that the radial runout relative to the center of the steel wire raceway is not greater than 0.03 mm. If the cylinder is off, all cams installed relative to it will also be off.
For the replacement of cam boxes, the core actions are “matching each to its correct position” and rechecking clearance block by block. The clearance between the dial or cylinder and the cams is 0.10—0.20 mm, and the unevenness at all points is not greater than 0.05 mm; when adjusting, turn in the adjusting screw while measuring point by point with a feeler gauge. After locking, recheck; if there is any change, adjust repeatedly until qualified.
The standard for sinker cams is to make the sinker yarn-pressing recess form a 90-degree angle with the raised needle, leaving about 0.5 mm clearance between the recess and the needle; attach a dial indicator to the inside of the cylinder, point the probe at the highest point of the sinker protrusion, and calibrate block by block while jogging.
The installation accuracy of the yarn guide directly determines whether knitting can be established. Taking a double jersey machine as an example, the rear of the yarn guide is about 0.5 mm from the lower needle hook, the bottom is about 0.5 mm from the dial needle hook, and the right side is about 2 needle pitches from the needle that begins to close its latch. If the deviation is too large, dropped stitches, tuck defects, and holes will immediately appear on the fabric.
---
III. Adjustment: Verify the Datum
The adjustment sequence must be static first and dynamic second, geometry first and process second.
1. First verify the “static” geometric accuracy
Use a dial indicator or feeler gauge to inspect six core indicators; the standard is usually not greater than 0.05 mm for all: dial self-flatness, dial self-roundness; cylinder self-roundness, cylinder self-flatness; and the coplanarity and concentricity between the dial and the cylinder.
Concentricity adjustment method: loosen the cylinder locking screws, use a dial indicator to adjust the concentricity of the cylinder relative to the main table, and lock the eccentric positioning wheels; then loosen the connecting screws between the upper leg and the large crown. Attach the dial indicator to the upper surface of the dial with the probe pointing to the outer diameter of the cylinder. Jog the machine and adjust the upper leg adjusting block so that the reading is not greater than 0.05 mm. After locking, jog and recheck again; the reading must still remain within 0.05 mm. It is common for the reading to “run off” after locking, so repeated operation is required until it is consistent before and after locking.
2. Then adjust the “dynamic” process parameters
Tension uniformity takes priority over fabric weight. Measure each path with a tension meter. When the tension fluctuation range is too large, go back and check the geometric accuracy of the cylinder and dial, rather than staring only at the tensioner.
Stitch cam depth and fabric weight are adjusted through the raising/lowering ring: when the cam box lowers with the raising/lowering ring, the loops lengthen and the fabric weight decreases; when it rises, the loops shorten and the fabric weight increases. When adjusting fabric weight, the yarn input tension must be recalibrated at the same time—the input tension is about 4—5 gf for open fabric and about 2—3 gf for dense fabric. Increasing the stitch cam depth also increases the knitting tension; beyond a certain point, the yarn will break in the knitting zone. Therefore, the adjustment range should be small each time, and the tension must be rechecked after adjustment.
3. Drive and safety verification
Apply 1—1.8 kg pressure to the middle section of the motor drive belt; the linear deformation should not be greater than 3.5 mm. On first power-up, the motor rotation direction must be confirmed immediately; reverse rotation is strictly prohibited, otherwise needles will easily bend or break. The inverter usually adopts V/F mode, about 6 Hz for jogging and up to 70 Hz for normal knitting, and DC braking is set to prevent post-stop rotation.
---
IV. Fabric Verification: Use the Direction of Fabric Defects to Locate Causes
Fabric defects are results, not causes. Sorting by “direction” is more effective than tightening screws one by one:
· Vertical holes or vertical stripes: usually point to evidence at a fixed position, such as the condition of a certain needle, or the position or wear of a certain yarn feeder.
· Density unevenness or horizontal stripes across the full width: point to tension or yarn batch, such as uneven tension between yarn feeders, mixed yarn batches, or fluctuation in the condition of the feed wheel.
· Intermittent faults with no fixed pattern: check sensors, stop-motion devices, and lubrication condition first.
When changing to a new yarn batch, do not run at full speed immediately. Introduce the yarn at low speed and inspect the first roll of fabric, because differences in yarn twist between batches will change loop behavior.
---
V. Key Safety Reminders
· No reverse rotation: Never reverse or turn back the motor during operation, otherwise needles will easily bend or break.
· Lint fan: Check the blade screws weekly to prevent them from loosening and flying off.
· Electrical safety: Wiring and inverter parameter adjustments must be performed by certified personnel. Disconnect power and confirm no residual voltage before working.
· Adjustment discipline: Never adjust mechanical parts at high speed or while energized; the adjustment range should be small each time, and rechecking must be performed after adjustment.